Columns are one of the most crucial load-bearing elements in any structure. Their primary function is to transfer loads from the slabs and beams down to the foundation. Proper column design ensures structural stability, durability, and safety.
This article provides a comprehensive understanding of column design, including types of columns, thumb rules, load calculations, reinforcement detailing, and practical considerations.
📌 What is a Column?
A column is a vertical structural member designed to transfer compressive loads from the structure above to the foundation below. Depending on its position, load type, and shape, the column design will vary.
🧱 Types of Columns (Based on Various Criteria)
Based on Shape
- Rectangular or Square Columns: Common in residential buildings.
- Circular Columns: Often used in aesthetic or infrastructural applications.
- L-shaped, T-shaped, or Hexagonal Columns: Used where architectural or structural requirements demand.
Based on Load-Carrying Capacity
- Axially Loaded Column: Load passes through the centroid.
- Eccentrically Loaded Column: Load acts at some eccentricity from the centre.
- Biaxially Loaded Column: Load acts with bending about both axes.
Based on Reinforcement
- Tied Column: Lateral ties hold longitudinal bars.
- Spiral Column: Helical reinforcements are used.
- Composite Column: Concrete-filled steel tubes or reinforced steel columns.
📏 Thumb Rules for Column Design
Before performing a detailed structural analysis, some basic thumb rules help in preliminary column layout:
✅ Size of Column
- Minimum size for an RCC column should be 9” x 9” (225mm x 225mm) with 4 nos. of 12mm dia bars, used only in single or two-story buildings.
- For multi-storey buildings: 12” x 12” (300mm x 300mm) or larger is common.
✅ Spacing Between Columns
- Ideal spacing: 3m to 5m.
- Avoid spans >6m without proper beams or intermediate columns.
✅ Minimum Reinforcement in Column
- Longitudinal Reinforcement: 0.8% to 6% of the cross-sectional area.
- Lateral Ties: 8mm or 10mm dia spaced at 150mm to 300mm c/c.
✅ Clear Cover to Reinforcement
- Usually 40mm for columns exposed to the weather.
- Can be reduced to 25mm in internal columns.
🧮 Column Load Calculation (Step-by-Step)
Let’s break down how to calculate the axial load on a column and size it properly.
Step 1: Calculate Total Load on a Column
Total load = Dead Load (DL) + Live Load (LL) + Floor Finish + Wall Load
Example:
Assume a residential column supports:
- Slab load = 4 kN/m²
- Live load = 2 kN/m²
- Floor finish = 1 kN/m²
- Wall load = 10 kN
- Tributary area = 3m × 4m = 12 m²
- Number of floors = 3
Load per floor = (4 + 2 + 1) × 12 + 10 = 7 × 12 + 10 = 94 kN
Total load = 94 × 3 = 282 kN
Step 2: Add the Self-Weight of the Column
Assume column size = 300mm x 300mm, height = 3m
Self-weight = Volume × Density
= 0.3 × 0.3 × 3 × 25 = 6.75 kN (approx.)
Total design load (including self-weight and factor of safety) ≈ 1.5 × (282 + 6.75) = 433 kn
🧮 Column Size and Reinforcement Calculation
Minimum Area Required for Concrete
Using permissible compressive stress of M20 concrete and Fe500 steel.
Use:
Pu = 0.4 × fck × Ac + 0.67 × fy × Asc
Where:
Pu = Ultimate load
fck = 20 MPa
fy = 500 MPa
Ac = Area of concrete
Asc = Area of steel
A trial-and-error approach or software like STAAD/ETABS is used for precision, but a safe size can be taken as:
- 300mm × 300mm column with 4-6 nos.. of 16mm dia bars.
Longitudinal Reinforcement
- Minimum: 0.8% of cross-section
= 0.8/100 × (300×300) = 720 mm²
4 nos.. of 16mm dia bars = 804 mm² → OK
Lateral Ties / Stirrups
- Use 8mm dia ties @ 150mm c/c spacing
- Tie spacing: the lesser of:
- Least lateral dimension (300mm)
- 16× diameter of main bar (16×16 = 256mm)
- 48× diameter of tie (48×8 = 384mm)
So, use 150mm spacing.
🧱 Column Reinforcement Detailing Guidelines
Element | Standard Practices |
Longitudinal Bars | Minimum 4 bars for rectangular, 6 for circular. |
Spacing of Ties | 150mm to 300mm c/c (closer near joints and base) |
Lap Length (for bars) | 50 × diameter of bar (for compression) |
Clear Cover | 40mm for external, 25mm for internal columns |
Hooks in Ties | 135° standard hook with 10 × diameter extension |
🛠️ Practical Tips for Site Engineers
- Avoid thin columns (<225mm) even in single-story buildings.
- Check alignment and verticality with a plumb bob or laser.
- Use column boxes with proper bracing to prevent bulging during concreting.
- Apply shuttering oil to the column box before casting.
- Ensure proper compaction to avoid honeycombs.
- Keep steel clean, rust-free, and of appropriate lap length.
- Always double-check the bar bending schedule (BBS).
📋 IS Code Reference for Column Design
- IS 456:2000 – Code of practice for Plain and Reinforced Concrete
- IS 13920:2016 – Ductile detailing of reinforced concrete structures
- SP 16 – Design Aids for Reinforced Concrete (Handy tables
🧠 Conclusion
Column design is a critical structural activity that combines theoretical calculations and field experience. Using thumb rules for preliminary design and then validating through detailed analysis ensures structural safety and cost-effectiveness. Always follow IS codes and best site practices to ensure the durability and performance of your columns.